Desco 09813

Floor & Worksurface Ground Cord with Resistor & 10mm Stud, 15'

In Stock
  • Low profile - Reduces inadvertent snagging that may disconnect ground cord
  • 10mm (0.395") snap stud - Easily snaps to mat 10mm socket snap, flush to mat surface
  • Stud has threaded hole; 6-32x1/4" flat head screw and countersunk washer are provided - Allows ground cord to be optionally bolted to the mat to keep the cord from disconnecting; ensures proper grounding.
  • Available as a kit - 14234 kit includes one 09813 ground cord and one 09864 universal snap kit
  • Ring terminal at end of ground cord - Allows easy attachment to electrical ground
  • Versatile - Can be used with worksurface mat or floor mat
  • Includes 1 Megohm Resistor, meets Grounding standard ANSI/ESD S6.1 - No resistor is required, but with resistor is acceptable
  • Made in The United States of America
$17.56

Grounding per ESD Association

The first step in ensuring that everything in an EPA is at the same electrical potential is to ground all conductive components of the work area (i.e., worksurfaces, people equipment, etc.) to the same electrical ground point. This point is called the common point ground and is defined by ANSI/ESD S6.1 as 'a system or method for connecting two or more grounding conductors to the same electrical potential.' ...The next step in completing the ground circuit is to connect the common ground point to the AC equipment ground an auxiliary ground, as defined in ANSI/ESD S6.1 [ESD Handbook ESD TR20.20 section 5.1.3 Basic Grounding Requirements]

The grounding conductors (wires) from wrist straps, worksurfaces, flooring or floor mats, tools, fixtures, storage units, carts, chairs, garments, and other ESD technical elements may or may not contain added resistance. Where added resistance is not present, a direct connection point is acceptable and recommended.

Note: Manufacturers may add resistance to the grounding conductors for purposes other than ESD (e.g. current limiting). Added resistance is acceptable for the purposes of controlling ESD provided electrostatic accumulation does not exceed specific EPA requirements. The typical added resistance in grounding conductors is 1 megohm, although other values may be specified." [Grounding ANSI/ESD S6.1-2009 section 5.3.3 ESD Technical Element Conductors]

The resistance of the conductor from the groundable point ground of any ESD technical element (e.g. worksurface, floor, chair, wrist strap, etc.) to the common point or common connection point shall not be greater than 1 ohm. Where a resistor is used in the grounding conductor, the total resistance shall include the value of the resistor. [Grounding ANSI/ESD S6.1-2009 section 6.4.1]

More Information
SKU I142560
Mfg. Part Number 09813
Brand Desco
Length 15'